Research library

Lab measurement

Assessing the efficacy of pyrolysis-gas chromatography-mass spectrometry for nanoplastic and microplastic analysis in human blood

Rauert C, Charlton N, Bagley A, Dunlop SA, Symeonides C, Thomas KV (2025). Environmental Science & Technology.

What they found

Tested whether pyrolysis-GC/MS can reliably measure plastic in human blood. Blood produced false polyethylene and PVC signals; a new extraction reduced but did not remove the polyethylene interference, realistic detection limits were up to 20 times higher than in clean water, and in the pilot no other polymer exceeded detection limits. The authors conclude the method is currently not suitable for PE and PVC in biological samples.

Sample
Method validation plus a pilot of Australian blood samples
What it can't tell you
One lab's protocol and a small pilot; better clean-up methods may solve the interference. Extraction recoveries varied widely (7–109%). It does not show that earlier detections were wrong, only that PE and PVC readings by this method are unreliable.
Funding
Minderoo Foundation
Topics
In the body, Methods
Checked against
Abstract (Europe PMC, PMID 39851066, PMC11800385); funder via Crossref

Where we cite it